Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0973

Calculate efficiency using useful energy output

Divide the useful share by the full input and keep consistent units, boundaries and intervals.

Section P1.7.3 · Energy resources

Energy resources · Cambridge IGCSE 0973 · P1.7.3
Exam scope and assessment notes

Mapped to the named 0973 section using teaching from the corresponding single-science course. A 0973-specific review of every Core and Supplement objective is still in progress. Written practice is self-checked; it does not demonstrate supervised laboratory competence or award an official Cambridge grade. This qualification reports two grades on the 9–1 scale; confirm the entry route for your zone and exam series.

Before you begin

  • Identify the intended useful output.
  • Convert kilojoules to joules and use percentages.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

Which fraction represents 40%?

What you will learn

  • Recall efficiency = useful energy output / total energy input.
  • Convert between fraction and percentage and find missing amounts.
Original complete input/output comparisons show 200 J input with 120 J useful and 80 J other energy, and 1000 W input with 350 W useful and 650 W other power. Each full input has width 260 drawing units; useful and other widths are their fractions of that input, so each pair sums to 260. The two rows are separately normalised shares, not a common joule-versus-watt magnitude scale. Useful output is defined by the task. The numerical efficiency equations and percentage calculations belong to Supplement teaching.Useful share of a complete inputFull input: 200 JUseful 120; other 80 JFull input: 1000 WUseful 350; other 650 WEach full input has the same widthShares, not a shared J / W scale
Original complete input/output comparisons show 200 J input with 120 J useful and 80 J other energy, and 1000 W input with 350 W useful and 650 W other power. Each full input has width 260 drawing units; useful and other widths are their fractions of that input, so each pair sums to 260. The two rows are separately normalised shares, not a common joule-versus-watt magnitude scale. Useful output is defined by the task. The numerical efficiency equations and percentage calculations belong to Supplement teaching.

The denominator is the full input

Efficiency as a fraction is useful energy output divided by total energy input. Multiply by 100% for percentage efficiency. For 200 J input and 120 J useful output, the fraction is 0.60 and efficiency is 60%. The remaining 80 J has other conserved destinations; it is not deleted from the input denominator.

Use matching units and the same event, boundary and interval. A 2.0 kJ input is 2000 J, so 500 J useful output gives fraction 0.25 or 25%. Dividing 500 by 2 without converting units gives a meaningless result. If the account includes an additional energy source or an initial store decrease, include it in the full relevant input rather than claiming a conversion exceeds its complete input.

Rearrange a complete account

Useful output = efficiency fraction × total input. At 40% efficiency and 300 J input, useful output is 120 J and other transfers are 180 J in an exhaustive account. If 150 J useful output is required at 30%, total input is 150/0.30 = 500 J. A percentage value of 30 means fraction 0.30, not thirty times the input.

At the same useful task and consistent full boundary, a larger useful fraction means higher efficiency. It need not mean a larger useful amount if input quantities differ. A reported ordinary conversion value above 100% requires checking units, boundaries, omitted inputs or measurements. Heating-system ratios using additional environmental energy cannot be called this complete-input conversion efficiency by ignoring that energy source.

Sources for this lesson

Pause and explain

What denominator belongs in efficiency for 200 J input with 120 J useful and 80 J other output?

Put the idea to work

Worked example

A device receives 200 J and supplies 120 J to its stated useful task. Find fraction, percentage and the exhaustive other share.

Show the worked solution
  1. Fraction = 120/200 = 0.60.
  2. Percentage = 0.60 × 100% = 60%.
  3. Other destinations receive 200 − 120 = 80 J.

Answer 0.60 or 60%; other share 80 J.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Find efficiency and the other share for 200 J input and 120 J useful output.

Give me a hint

Use the whole input and then an exhaustive difference.

Compare my reasoning
  1. Fraction = 120/200 = 0.60.
  2. Percentage = 60%.
  3. Other share = 80 J.

60%; 80 J other output.

Look for these in your work

  • Use the full denominator.
  • Account for the remaining conserved energy.
2 · Independent

Find efficiency for 500 J useful from 2.0 kJ input, and useful output from 300 J input at 40%.

Give me a hint

Convert input units and percentage fractions before calculating.

Compare my reasoning
  1. 2.0 kJ = 2000 J, so 500/2000 = 25%.
  2. 40% is fraction 0.40.
  3. Useful output = 0.40 × 300 = 120 J.

25%; 120 J.

Look for these in your work

  • Use matching units.
  • Multiply by the fraction, not forty.
3 · Transfer

A device is claimed to supply 150 J usefully at 30% using only 300 J complete input. Check the numbers and find the input actually required by that efficiency.

Give me a hint

Compare the claimed ratio and the rearranged input.

Compare my reasoning
  1. 150/300 = 50%, not 30%.
  2. At 30%, input must be 150/0.30.
  3. The required input is 500 J; the original combined claim is inconsistent.

The claim gives 50%; 30% would require 500 J input.

Look for these in your work

  • Check rather than accept inconsistent labels.
  • Keep a complete input boundary.

Common mistakes

  • Divide by full input, not wasted share.
  • Convert units before the ratio.
  • Use percentage as a fraction when rearranging.
Recall without your notes

What can you explain now?

What input supplies 150 J usefully at 30%?

Compare with the explanation

500 J.

150/0.30 = 500 J for the consistent supplied account.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Recall energy efficiency, convert units, find missing input or output and identify a boundary or percentage error.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Sciences — Co-ordinated (9-1)

Course scope and assessment

This 9–1 pathway maps all 152 detailed subject-content sections in the published 0973 syllabus for exams in 2028 and 2029. The course map follows the same 2028–2029 section codes as Cambridge's A*–G 0654 syllabus, while keeping 0973's grading and entry rules separate. It adapts lessons from the related single-science courses and excludes clear single-science-only topics. A 0973-specific objective-by-objective review, Core/Supplement audit, human subject-teacher review, supervised laboratory experience and cumulative assessment remain in progress. Written practice is self-checked and does not predict an official grade. The separate 2025–2027 syllabus has not been reconciled here. Cambridge lists 0973 only in a limited number of administrative zones: June in zone 3 and centres in Oman and the UAE; November in zone 3 only. Confirm entry with your centre.

StudyForA · Learn with understanding

Original teaching content and links to official sources. Check your exam year and qualification before using a resource.