Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0625

Use a digital voltmeter with a suitable parallel connection

Interpret signed digital voltage displays and range limits while distinguishing resolution, loading and source conditions.

Voltage and source work pathway · 4.2.3

Core and Extended; Physics 0625, 2026–2028. Use the stated source, operating conditions and meter ranges. Written practice is self-checked.

Before you begin

  • Connect a voltmeter in parallel.
  • Interpret volt prefixes and chosen polarity.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

What is 420 mV in volts?

What you will learn

  • Describe digital p.d. measurement with appropriate range and terminals.
  • Interpret sign, prefixes and the limits of display resolution.
Original digital voltmeter reference displays +4.20 V on a stated 20 V range. Reversing the same leads gives −4.20 V for unchanged conditions. High meter resistance limits loading; an overload does not mean zero voltage.Digital voltage reading20 V range: +4.20 VReverse leads: −4.20 VRead digits and unitsOverload is not zeroResolution ≠ accuracyConnect across component
Original digital voltmeter reference displays +4.20 V on a stated 20 V range. Reversing the same leads gives −4.20 V for unchanged conditions. High meter resistance limits loading; an overload does not mean zero voltage.

Record the two-terminal reference

Connect the digital voltmeter's voltage terminals across the two points in the isolated low-voltage measurement. A display of +4.20 V means the first stated terminal is at higher potential than the second under the meter's reference. Reversing the leads can give −4.20 V for the same physical p.d. with the reference reversed.

Choose a range above the expected magnitude. If the meter displays an overload indication, do not record it as zero p.d.; follow its instructions and select a larger suitable range. A 420 mV display is 0.420 V, not 420 V, so retain the displayed unit and prefix with the digits.

Know what the meter can establish

A stated 0.01 V display step gives voltage resolution. It does not alone prove an accuracy of exactly 0.01 V. A high-resistance voltmeter draws relatively little current, but its effect can still matter in a sensitive circuit; an ideal meter approximation must be stated when used.

An open-circuit source reading can approximate e.m.f. when the meter's current is negligible. A loaded real source's terminal reading need not equal its e.m.f. because of internal energy transfers. Record whether the source was loaded rather than treating every voltage display as the same source quantity.

Pause and explain

Reversing voltage leads changes +4.20 V to −4.20 V. What changed?

Put the idea to work

Worked example

A digital voltmeter gives +4.20 V. The same two points are measured with reversed leads. Interpret the expected sign change in the ideal reading.

Show the worked solution
  1. The physical pair of points is unchanged.
  2. The measurement polarity is reversed.
  3. The magnitude stays 4.20 V and the sign reverses.

Answer −4.20 V on the reversed reference.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Interpret a +4.20 V reading and its −4.20 V value after reversing the leads across the same points.

Give me a hint

Distinguish the physical magnitude from the chosen reference.

Compare my reasoning
  1. The p.d. magnitude is 4.20 V.
  2. Reversed leads swap the reference points.
  3. The sign reverses while the ideal magnitude remains.

Same 4.20 V magnitude; opposite measurement reference.

Look for these in your work

  • State the magnitude.
  • Explain the sign convention.
2 · Independent

Convert 420 mV to V and identify what a 0.01 V display step establishes.

Give me a hint

Convert the prefix, then distinguish resolution from accuracy.

Compare my reasoning
  1. 420 mV = 0.420 V.
  2. The step is 0.01 V resolution.
  3. Accuracy is not established by that step alone.

0.420 V; resolution 0.01 V, with accuracy not determined from the step alone.

Look for these in your work

  • Convert the displayed unit.
  • Separate resolution and accuracy.
3 · Transfer

A loaded cell's terminal display is called its exact e.m.f. without any source assumptions. Assess the interpretation.

Give me a hint

Identify the terminal account and possible source-internal transfers.

Compare my reasoning
  1. The meter measures terminal p.d.
  2. A real loaded source can transfer energy internally.
  3. Equality with e.m.f. requires an appropriate ideal or negligible-current condition.

The display is terminal p.d.; exact equality with e.m.f. is not established.

Look for these in your work

  • Name the measured quantity.
  • State the missing source condition.

Common mistakes

  • Read voltage terminals and prefixes.
  • Overload is not zero p.d.
  • Resolution and loaded terminal p.d. have separate limitations.
Recall without your notes

What can you explain now?

Does a 0.01 V display step alone prove an accuracy of 0.01 V?

Compare with the explanation

No.

The step specifies resolution; accuracy requires the supplied meter specification.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Interpret digital p.d. with range, polarity, resolution and explicit source-loading conditions.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Physics

Course scope and assessment

491 sequenced Physics lessons provide 1473 guided, independent and application problems. 58 of 58 syllabus sections have full linked teaching sequences; 0 sections remain pending. Three earlier starter overviews remain available but are not counted as full sequences. The map covers all six subject areas for 2026–2028 and keeps review and assessment limits visible. This is available content, not full programme completion, an exam grade or certified mastery. Written practice is self-checked. Supervised practical experience, cumulative assessment and human subject-teacher review remain pending. Paper method exercises do not demonstrate practical competence or complete either practical-assessment route.

StudyForA · Learn with understanding

Original teaching content and links to official sources. Check your exam year and qualification before using a resource.