Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0973

Calculate ideal transformer input and output currents

Use IpVp = IsVs for a stated 100%-efficient transformer with matched power quantities and suitable load assumptions.

The transformer · Cambridge IGCSE 0973 · P4.5.6
Exam scope and assessment notes

Mapped to the named 0973 section using teaching from the corresponding single-science course. A 0973-specific review of every Core and Supplement objective is still in progress. Written practice is self-checked; it does not demonstrate supervised laboratory competence or award an official Cambridge grade. This qualification reports two grades on the 9–1 scale; confirm the entry route for your zone and exam series.

Before you begin

  • Use P = IV under stated conditions.
  • Rearrange a product equality.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

Which equality is required by ideal efficiency?

What you will learn

  • Use IpVp = IsVs for a stated 100%-efficient transformer with matched power quantities and suitable load assumptions.
  • Calculate ideal transformer currents from matched powers and retain real-load and no-load limits.
Original 100%-efficient loaded model has primary 240 V, secondary 12 V and secondary current 2 A. Both matched power products are 24 W and primary current is 0.10 A. Suitable matched a.c. magnitudes and the supplied resistive-load account are assumed; real no-load current is not inferred.100%-efficient loaded modelVp = 240 V · Vs = 12 VIs = 2 AIp = 0.10 APin = Pout = 24 WCorresponding a.c. magnitudesSupplied resistive-load accountReal no-load current not inferred
Original 100%-efficient loaded model has primary 240 V, secondary 12 V and secondary current 2 A. Both matched power products are 24 W and primary current is 0.10 A. Suitable matched a.c. magnitudes and the supplied resistive-load account are assumed; real no-load current is not inferred.

Apply the stated ideal power balance

For a transformer with 100% efficiency in the supplied simple power model, input power equals output power: IpVp = IsVs. The primary and secondary quantities must refer to the same operating state and use consistent voltage and current units. The exercise uses suitable matched a.c. magnitudes and a resistive-load power account; do not apply it unqualified to arbitrary phase-shifted loads.

For Vp = 240 V, Vs = 12 V and Is = 2 A, output power is 24 W. Input current is Ip = 24/240 = 0.10 A. Lower output voltage can accompany greater output current while power is conserved. The primary and secondary currents are not equal merely because the transformer is ideal.

Keep real and no-load cases separate

Real transformer losses mean the ideal equality does not establish actual efficiency. With an open secondary, Is can be zero while a real primary still draws a magnetising and loss-related current. Do not use the ideal load calculation to claim every unloaded real primary current must be zero.

The current equation requires load information. A voltage-turn ratio alone cannot give a unique actual current in both circuits. State the 100%-efficiency assumption before rearranging; output power cannot exceed input power in that passive ideal account.

Sources for this lesson

Pause and explain

Vp = 120 V, Vs = 24 V, Is = 0.50 A. What is ideal Ip?

Put the idea to work

Worked example

A supplied ideal transformer has Vp = 240 V, Vs = 12 V and Is = 2 A. Find Ip and both powers.

Show the worked solution
  1. Output power is 12 × 2 = 24 W.
  2. Ideal input power is also 24 W.
  3. Ip = 24/240 = 0.10 A.

Answer Ip = 0.10 A; input and output powers 24 W.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Find Ip for Vp = 240 V, Vs = 12 V and Is = 2 A.

Give me a hint

Compute output power before dividing by primary voltage.

Compare my reasoning
  1. Pout = 24 W.
  2. Pin = 24 W under the ideal assumption.
  3. Ip = 24/240 = 0.10 A.

0.10 A.

Look for these in your work

  • State the ideal condition.
  • Retain amperes.
2 · Independent

Find Ip for Vp = 120 V, Vs = 24 V and Is = 0.50 A.

Give me a hint

Use the same-state power products.

Compare my reasoning
  1. Pout = 24 × 0.50 = 12 W.
  2. Ideal Pin = 12 W.
  3. Ip = 12/120 = 0.10 A.

0.10 A.

Look for these in your work

  • Use the output load current.
  • Check equal powers.
3 · Transfer

A supplied ideal step-up has Vp = 12 V, Ip = 2 A and Vs = 120 V. Find Is and explain why higher output voltage is not greater output power.

Give me a hint

Conserve the 24 W input product.

Compare my reasoning
  1. Input power is 12 × 2 = 24 W.
  2. Is = 24/120 = 0.20 A.
  3. Greater output voltage accompanies smaller current at unchanged ideal power.

Is = 0.20 A; both powers 24 W.

Look for these in your work

  • Use inverse current change.
  • Reject energy creation.

Common mistakes

  • State ideal efficiency.
  • Use matching operating quantities.
  • Do not set primary and secondary current equal.
Recall without your notes

What can you explain now?

What does 100% efficiency imply for the supplied transformer power account?

Compare with the explanation

Input power equals output power

The ideal account equates the primary and secondary power rather than their voltages or currents individually.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Calculate ideal transformer currents from matched powers and retain real-load and no-load limits.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Sciences — Co-ordinated (9-1)

Course scope and assessment

This 9–1 pathway maps all 152 detailed subject-content sections in the published 0973 syllabus for exams in 2028 and 2029. The course map follows the same 2028–2029 section codes as Cambridge's A*–G 0654 syllabus, while keeping 0973's grading and entry rules separate. It adapts lessons from the related single-science courses and excludes clear single-science-only topics. A 0973-specific objective-by-objective review, Core/Supplement audit, human subject-teacher review, supervised laboratory experience and cumulative assessment remain in progress. Written practice is self-checked and does not predict an official grade. The separate 2025–2027 syllabus has not been reconciled here. Cambridge lists 0973 only in a limited number of administrative zones: June in zone 3 and centres in Oman and the UAE; November in zone 3 only. Confirm entry with your centre.

StudyForA · Learn with understanding

Original teaching content and links to official sources. Check your exam year and qualification before using a resource.