Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0973

Describe a controlled infrared absorption experiment

Compare temperature rises under matched source and sample conditions and separate absorption from emission.

Radiation · Cambridge IGCSE 0973 · P2.3.3
Exam scope and assessment notes

Mapped to the named 0973 section using teaching from the corresponding single-science course. A 0973-specific review of every Core and Supplement objective is still in progress. Written practice is self-checked; it does not demonstrate supervised laboratory competence or award an official Cambridge grade. This qualification reports two grades on the 9–1 scale; confirm the entry route for your zone and exam series.

Before you begin

  • Distinguish absorption from emission.
  • Use temperature change and identify thermal-property differences.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

Which arrangement best isolates a surface-finish absorption comparison?

What you will learn

  • Describe an experiment distinguishing good and bad infrared absorbers.
  • Identify source, geometry, sample-property and outgoing-transfer controls.
Original absorption method compares matched samples under equal infrared exposure geometry, duration, initial temperature and suitable thermal properties. Supplied 20-to-26°C and 20-to-22°C changes are 6 K and 2 K. Temperature rise measures net energy gain; outgoing routes still matter to exact absorbed power. Shapes and beam paths are qualitative, not measured geometry or a performed laboratory assessment.Matched source and sample properties20°C → 26°C: rise 6 K20°C → 22°C: rise 2 KInfrared source → sampleRise records net gain, not input alone
Original absorption method compares matched samples under equal infrared exposure geometry, duration, initial temperature and suitable thermal properties. Supplied 20-to-26°C and 20-to-22°C changes are 6 K and 2 K. Temperature rise measures net energy gain; outgoing routes still matter to exact absorbed power. Shapes and beam paths are qualitative, not measured geometry or a performed laboratory assessment.

Match source exposure and sample response

In a teacher-supervised method, use suitable comparable objects with different finishes, such as dull black and shiny light surfaces. Match material, mass, exposed area and initial temperature as closely as the method allows. Place them at the same distance and orientation to a suitable infrared source and expose them for the same time, with comparable surrounding airflow and other conditions.

Measure representative initial and final temperatures using an appropriate method. A greater rise for the dull black sample under a suitable controlled comparison supports stronger absorption in the standard school model. Do not put one surface closer to the source or give it a smaller thermal mass and then attribute the whole response to the finish.

Net temperature rise is not absorption alone

The samples can also emit, convect and conduct during the trial. A temperature rise records net energy gain; the initial or short-time comparison with matched properties can help investigate absorption, but exact absorbed power needs those other transfers and thermal properties accounted for. A larger rise is not a direct detector reading of total incident radiation.

For supplied comparable samples, rises of 6 K and 2 K support a different net response under the stated controls; they do not alone establish a universal three-to-one absorption property. Repeat suitable measurements, control position and monitor conditions. This is a written experiment plan and supplied-data exercise, not a completed laboratory assessment.

Sources for this lesson

Pause and explain

Samples warm from 20°C to 26°C and 22°C. What are their temperature rises?

Put the idea to work

Worked example

Comparable samples begin at 20°C and reach 26°C and 22°C after matched infrared exposure. Interpret the supplied rises.

Show the worked solution
  1. Rises are 6 K and 2 K.
  2. The first has the greater net heating response under the stated controls.
  3. With suitable matched conditions this supports stronger absorption, but an exact universal absorbed-power ratio is not established.

Answer Rises 6 K and 2 K; the first has the greater controlled net response.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Describe the different-finish absorption experiment and its temperature measurements.

Give me a hint

Match exposure and thermal properties before comparing rises.

Compare my reasoning
  1. Use comparable samples at matched initial temperatures and source geometry.
  2. Expose for the same time and measure representative final temperatures.
  3. Compare rises while considering outgoing transfers and repeats.

A controlled source-exposure and temperature-rise comparison supports the absorption investigation.

Look for these in your work

  • Name the controls.
  • Retain the net-response limit.
2 · Independent

Compute rises for samples starting at 20°C and ending at 26°C and 22°C. What response comparison is supported?

Give me a hint

Use final minus initial without converting the intervals by an offset.

Compare my reasoning
  1. The rises are 6 K and 2 K.
  2. The first has the greater net temperature response.
  3. A universal exact absorption ratio needs more energy-account evidence.

6 K and 2 K; greater first-sample net response.

Look for these in your work

  • Use intervals correctly.
  • Limit the absorption claim.
3 · Transfer

The black sample warms more but has half the mass and is closer to the source. Can the result isolate finish? Improve the method.

Give me a hint

Mass and source geometry are alternative causes of the result.

Compare my reasoning
  1. Match sample material, mass, area and initial temperature.
  2. Match source distance, orientation, duration and surrounding conditions.
  3. Repeat and evaluate other outgoing transfers before a finish-only conclusion.

No; match sample thermal properties and source exposure before attributing the difference to finish.

Look for these in your work

  • Identify both confounders.
  • Keep the measurement limitations.

Common mistakes

  • Match mass, material, start temperature, distance, area and time.
  • A temperature rise measures net gain, not absorption alone.
  • Keep emission and absorption experiments distinct.
Recall without your notes

What can you explain now?

Why does unequal sample mass confound a temperature-rise absorption comparison?

Compare with the explanation

Temperature response depends on thermal mass as well as energy gain.

Different masses can give different rises even if the absorbed energy were equal.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Describe absorption testing with matched exposure and thermal properties, then distinguish net rise from absorbed power alone.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Sciences — Co-ordinated (9-1)

Course scope and assessment

This 9–1 pathway maps all 152 detailed subject-content sections in the published 0973 syllabus for exams in 2028 and 2029. The course map follows the same 2028–2029 section codes as Cambridge's A*–G 0654 syllabus, while keeping 0973's grading and entry rules separate. It adapts lessons from the related single-science courses and excludes clear single-science-only topics. A 0973-specific objective-by-objective review, Core/Supplement audit, human subject-teacher review, supervised laboratory experience and cumulative assessment remain in progress. Written practice is self-checked and does not predict an official grade. The separate 2025–2027 syllabus has not been reconciled here. Cambridge lists 0973 only in a limited number of administrative zones: June in zone 3 and centres in Oman and the UAE; November in zone 3 only. Confirm entry with your centre.

StudyForA · Learn with understanding