Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0652

Describe a magnet and coil induction experiment

Specify apparatus, controlled observations and repeated comparisons for a school induction demonstration.

Electromagnetic induction · Cambridge IGCSE Physical Science 0652 · P4.6.1

Cross-referenced from the related Cambridge IGCSE Chemistry 0620 or Physics 0625 teaching to the 0652 syllabus. Exact 0652 Core/Supplement objective coverage and this final-series course’s examiner fit still need specialist review. Written practice is self-checked and does not predict a Cambridge grade or demonstrate supervised laboratory competence.

Before you begin

  • Distinguish induced e.m.f. from current.
  • Read a signed centre-zero scale.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

What does a centre-zero detector allow you to observe?

What you will learn

  • Specify apparatus, controlled observations and repeated comparisons for a school induction demonstration.
  • Plan the apparatus, changing condition, stationary control and signed measurements of induction.
Original supplied centre-zero observations show approach +0.4 divisions, fixed hold zero and withdrawal −0.4 divisions with unchanged pole and terminals. Divisions are not volts or amperes without calibration. Written planning does not demonstrate practical competence.Unchanged pole and terminalsApproach: +0.4 divisionsChanging linked fieldFixed hold: zeroSteady linkingWithdrawal: −0.4 divisionsOpposite signed responseCalibration needed for A or V
Original supplied centre-zero observations show approach +0.4 divisions, fixed hold zero and withdrawal −0.4 divisions with unchanged pole and terminals. Divisions are not volts or amperes without calibration. Written planning does not demonstrate practical competence.

Use a sensitive detector and no supply in the receiver

Connect a school coil to a sensitive centre-zero galvanometer or suitable signed voltage detector. Move a bar magnet toward the coil, hold it still, then withdraw it. A deflection during movement and a zero return during the fixed hold demonstrate the changing-condition requirement. The receiving coil does not need an external electrical supply.

Keep coil orientation, magnet pole and detector connections unchanged while comparing approach and withdrawal. The two movements give opposite signs under the same connections. Swapping the approaching pole also reverses the sign. A meter sign is defined by its terminals; without that convention, positive does not name a universal direction.

Make comparisons controlled and repeatable

To compare speeds, keep the same magnet, coil, path and travel interval, move more slowly and more quickly, and compare peak deflection with repeated trials. To compare turns or magnet strength, change that one factor while holding speed, geometry and the detector circuit appropriately constant. Current measurements can also depend on circuit resistance.

The class demonstration uses suitable school apparatus, secure components and the teacher’s safety arrangements. Do not connect the receiving coil to mains. A written method checks planning and interpretation; it does not prove that the learner has performed an accurate practical or met the full practical-assessment requirements.

Sources for this lesson

Pause and explain

With magnet pole and terminals unchanged, approach and withdrawal produce what comparison?

Put the idea to work

Worked example

A coil detector gives +0.4 divisions on approach, 0 during hold and −0.4 on equal-speed withdrawal. Interpret without a supplied current calibration.

Show the worked solution
  1. Movement changes the linked field.
  2. Opposite movement reverses the sign with unchanged terminals.
  3. Divisions alone are not amperes or volts.

Answer Opposite signed deflections during change; no sustained hold response; calibration is needed for physical units.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Write a short magnet–coil induction method including approach, hold and withdrawal.

Give me a hint

Include apparatus and expected observations, not just the conclusion.

Compare my reasoning
  1. Connect a suitable coil to a sensitive centre-zero detector.
  2. Approach, hold and withdraw the magnet with unchanged pole and terminals.
  3. Expect a deflection, zero steady hold and an opposite deflection.

A controlled approach–hold–withdrawal sequence demonstrates induction and sign reversal.

Look for these in your work

  • Name the detector.
  • Include a stationary control.
2 · Independent

How would you compare magnet movement speeds fairly using detector peaks?

Give me a hint

Hold magnet, path, coil and measurement setup fixed.

Compare my reasoning
  1. Use the same pole and travel path.
  2. Compare slow and fast motion under unchanged circuit conditions.
  3. Repeat and compare peak magnitudes.

Change speed alone and compare repeated peak magnitudes.

Look for these in your work

  • Control the other factors.
  • Do not use a single uncontrolled reading as proof.
3 · Transfer

A report gives deflections +3 and −3 divisions but claims these are exactly ±3 A without a calibration. Correct it.

Give me a hint

A scale number needs its physical-unit relationship.

Compare my reasoning
  1. The signs identify opposite detector responses.
  2. Divisions measure indicated scale positions.
  3. A current calibration is required to convert them to amperes.

Report ±3 divisions and opposite signs; exact amperes are not established.

Look for these in your work

  • Preserve the observed evidence.
  • Identify the missing calibration.

Common mistakes

  • Keep terminals and pole fixed for a comparison.
  • Detector divisions are not automatically A or V.
  • No mains supply is needed in the receiving coil.
Recall without your notes

What can you explain now?

Why include the stationary hold in the experiment?

Compare with the explanation

It controls for a magnet being present without changing linking.

It separates steady-field proximity from the changing condition producing induction.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Plan the apparatus, changing condition, stationary control and signed measurements of induction.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Physical Science

Course scope and assessment

This page maps the 2025–2026 Cambridge IGCSE Physical Science 0652 syllabus: 38 Chemistry sections and 46 Physics sections. Every section links to original 0620/0625 teaching or one of five new 0652 lessons, with guided, independent and transfer practice and explained answers. Cambridge limits entry to Administrative Zone 3 and identifies November 2026 as the final exam series. The section crosswalk is complete as a first coverage map; a numbered-objective and Core/Supplement audit, independent subject-teacher review and cumulative assessment are still needed. Written practice does not award a Cambridge grade. Online activities cannot demonstrate supervised laboratory competence or complete Paper 5/6.

StudyForA · Learn with understanding

Original teaching content and links to official sources. Check your exam year and qualification before using a resource.