Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0972

Check pressure-volume data and model conditions

Compare supplied products and judge consistency without claiming proof of hidden controls.

Gases and absolute temperature pathway · 0972 (9–1) · 2.1.3
Exam scope and assessment notes

Extended only (Supplement) · Physics 0972, 2026–2028, section 2.1.3. Use pV = constant for a fixed gas mass at constant temperature, including the graphical relationship. Use absolute pressure and consistent units; a gauge reading alone is not the required absolute pressure. Core collision and temperature lessons should be studied first. Written practice is self-checked. Human subject-teacher review, supervised practical experience and cumulative assessment remain pending. Cambridge states that IGCSE 0972 has the same subject content as IGCSE 0625, with 9–1 grading. This StudyForA pathway maps the 2026–2028 syllabus only. This 9–1 graded qualification is available only in a limited number of administrative zones. Confirm that your centre can enter you for this code and exam series with Cambridge International. Cambridge has published a separate syllabus for 2029. StudyForA has not reconciled that version yet; this page supports exams in 2026, 2027 and 2028 only.

Before you begin

  • Calculate pV with absolute pressure and common units.
  • Identify what a supplied tolerance or uncertainty does and does not mean.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

What is 3% of 12 000?

What you will learn

  • Use pV products to check supplied states against a constant-product model.
  • Distinguish numerical consistency from proof of fixed mass, temperature or experimental quality.
An original supplied teaching table uses absolute pressure and common volume units: A is 120 kPa and 100 cm³, B is 200 kPa and 60 cm³, and C is 150 kPa and 85 cm³. Products are 12 000, 12 000 and 12 750 kPa cm³. A supplied ±3% interval about 12 000 is 11 640 to 12 360, so C is outside. These are illustrative values rather than recorded measurements. Matching products are numerical consistency, not independent proof of constant mass and temperature or practical competence.Supplied values · not new measurementsp / kPaV / cm³pVkPa cm³A12010012,000B2006012,000C1508512,750Reference 12 000 ±3%Accepted interval: 11 640–12 360C is outside the supplied intervalA product check does not prove controls
An original supplied teaching table uses absolute pressure and common volume units: A is 120 kPa and 100 cm³, B is 200 kPa and 60 cm³, and C is 150 kPa and 85 cm³. Products are 12 000, 12 000 and 12 750 kPa cm³. A supplied ±3% interval about 12 000 is 11 640 to 12 360, so C is outside. These are illustrative values rather than recorded measurements. Matching products are numerical consistency, not independent proof of constant mass and temperature or practical competence.

Calculate the product for each supplied row

An illustrative table lists A: 120 kPa and 100 cm³; B: 200 kPa and 60 cm³; C: 150 kPa and 85 cm³. Their products are 12 000, 12 000 and 12 750 kPa cm³. A and B match the proposed 12 000 product exactly; C is 750 above it, or 6.25% of the reference. These are supplied teaching values, not measurements recorded by this website.

If a question explicitly allows products within ±3% of 12 000, its acceptance interval is 11 640 to 12 360 kPa cm³. Row C is outside that supplied interval. Without a stated tolerance or measurement uncertainty, do not invent an experimental confidence claim or call every small numerical difference a proven temperature change.

A consistency check is not proof of every condition

Matching pV values are consistent with a fixed-mass, constant-temperature gas model, but they do not independently prove that mass and temperature were controlled. Evidence about apparatus, leaks and temperature is separate. A failed product check indicates a mismatch with the stated model and tolerance; it does not uniquely identify which measurement or control caused it.

Use positive absolute pressures and volumes before testing the product. Mixing gauge and absolute readings or incompatible units can create an artificial disagreement. First check the data's meanings, then calculate products and compare with the supplied acceptance rule. Written analysis of a table does not establish supervised practical competence.

Pause and explain

A row's product is 12 750 against 12 000 ±3%. What conclusion is justified?

Put the idea to work

Worked example

Check A = 120 kPa × 100 cm³, B = 200 kPa × 60 cm³ and C = 150 kPa × 85 cm³ against 12 000 kPa cm³ with a supplied ±3% product tolerance.

Show the worked solution
  1. The products are 12 000, 12 000 and 12 750 kPa cm³.
  2. The tolerance is ±360, giving 11 640 to 12 360 kPa cm³.
  3. A and B pass this numerical check; C fails it, without proving a unique cause.

Answer A and B are within tolerance; C is outside at 12 750 kPa cm³.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Check the three supplied rows A: 120 × 100, B: 200 × 60 and C: 150 × 85 in common kPa and cm³ units against 12 000 ±3%.

Give me a hint

Calculate products and the explicitly supplied acceptance interval.

Compare my reasoning
  1. Products are 12 000, 12 000 and 12 750 kPa cm³.
  2. The interval is 12 000 ±360, or 11 640 to 12 360.
  3. A and B fit it; C does not.

A and B pass the supplied product check; C fails.

Look for these in your work

  • Calculate all rows.
  • Use the stated tolerance.
2 · Independent

A table lists products 11 800, 12 200 and 12 400 kPa cm³. Which fit 12 000 ±3%, and what is the percentage excess of the last row over the reference?

Give me a hint

Apply the same interval and divide the excess by the reference.

Compare my reasoning
  1. The accepted interval remains 11 640 to 12 360.
  2. 11 800 and 12 200 fit; 12 400 does not.
  3. The excess is 400/12 000 × 100 ≈ 3.33%.

11 800 and 12 200 fit; 12 400 is outside at about 3.33% excess.

Look for these in your work

  • Compare with both interval boundaries.
  • Use the reference denominator.
3 · Transfer

Two rows have equal pV products, but no evidence of temperature control or constant gas mass is supplied. May the table prove both controls were maintained? Explain.

Give me a hint

Separate a numerical invariant from independent evidence of experimental conditions.

Compare my reasoning
  1. Equal products are consistent with the proposed model.
  2. The table does not independently establish fixed mass or temperature.
  3. Check the controls separately rather than claiming experimental proof from the product alone.

No; equal products show numerical consistency, not independent proof of both controls.

Look for these in your work

  • Distinguish consistency and proof.
  • Name the missing control evidence.

Common mistakes

  • Use the supplied tolerance rather than inventing one.
  • Matching products do not prove hidden controls.
  • A failed model check does not uniquely identify a fault.
Recall without your notes

What can you explain now?

Does matching pV alone prove both constant mass and temperature?

Compare with the explanation

No.

It supports numerical consistency; independent evidence is needed for the controls.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Check products and stated tolerance, then separate numerical agreement from evidence of conditions and practical competence.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Physics (9-1)

Course scope and assessment

491 sequenced Physics lessons provide 1473 guided, independent and application problems. 58 of 58 syllabus sections have full linked teaching sequences; 0 sections remain pending. Three earlier starter overviews remain available but are not counted as full sequences. The map covers all six subject areas for 2026–2028 and keeps review and assessment limits visible. This is available content, not full programme completion, an exam grade or certified mastery. Written practice is self-checked. Supervised practical experience, cumulative assessment and human subject-teacher review remain pending. Paper method exercises do not demonstrate practical competence or complete either practical-assessment route. This is the separate 9–1 qualification 0972; Cambridge states that its 2026–2028 subject content is otherwise the same as 0625. This 9–1 graded qualification is available only in a limited number of administrative zones. Confirm that your centre can enter you for this code and exam series with Cambridge International. The 2029 syllabus is separately published at https://www.cambridgeinternational.org/Images/764368-2029-syllabus.pdf and is not yet mapped here. This course supports exams in 2026, 2027 and 2028 only.

StudyForA · Learn with understanding

Original teaching content and links to official sources. Check your exam year and qualification before using a resource.