Control current comparisons in wire and solenoid fields

Keep geometry, material and current magnitude separate when interpreting direction and strength changes.

Magnetic effect of current pathway · 0972 (9–1) · 4.5.3
Exam scope and assessment notes

Extended only (Supplement) · Physics 0972, 2026–2028. Use the stated source, operating conditions and meter ranges. Written practice is self-checked. Human subject-teacher review, supervised practical competence and cumulative assessment remain pending. Cambridge states that IGCSE 0972 has the same subject content as IGCSE 0625, with 9–1 grading. This StudyForA pathway maps the 2026–2028 syllabus only. This 9–1 graded qualification is available only in a limited number of administrative zones. Confirm that your centre can enter you for this code and exam series with Cambridge International. Cambridge has published a separate syllabus for 2029. StudyForA has not reconciled that version yet; this page supports exams in 2026, 2027 and 2028 only.

Before you begin

  • Distinguish field strength from direction.
  • Use ammeter readings and controlled variables.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

Why use an ammeter in a current-magnitude comparison?

What you will learn

  • Keep geometry, material and current magnitude separate when interpreting direction and strength changes.
  • Match the controlled factor and measurement to a direction or strength claim without confusing current, voltage and field.
Original matched comparison isolates current magnitude or direction while holding geometry, material, core and sampling point fixed. Measure current rather than assuming that the same control setting keeps it unchanged. Changing both current and core confounds the comparison.Compare one current factorMagnitude or directionHold the other unchangedSame geometry, material and coreSame sampling pointMeasure the actual currentSame dial setting is not enough
Original matched comparison isolates current magnitude or direction while holding geometry, material, core and sampling point fixed. Measure current rather than assuming that the same control setting keeps it unchanged. Changing both current and core confounds the comparison.

Define the factor being investigated

To investigate current magnitude, use the same wire or solenoid, observation point, orientation, core condition and current direction while changing the measured magnitude. A variable current-limited supply and ammeter can establish the stated currents in a teacher-supervised setup. A suitable strength-sensitive observation is needed for a strength claim.

To investigate direction, reverse current at the same magnitude with winding, geometry and viewing side fixed. Then compare local compass north-tip directions or pole labels. Reversing current and turning the whole coil at the same time does not isolate the effect of current alone.

Judge the evidence and scope

A given report at a fixed point can support a qualitative stronger-field trend if the controlled larger current produces a stronger measured contribution. A direction-only reading cannot automatically establish a calibrated strength ratio. Two arbitrary field sketches with different line counts are not numerical experimental results.

School current limits and short observation intervals prevent unnecessary heating; do not use mains for a bare-wire demonstration. Temperature-related resistance changes can affect current unless the ammeter confirms it. A written comparison checks the experimental reasoning, not practical competence or instrument calibration.

Pause and explain

A comparison doubles current and turns the coil around. What can it isolate?

Put the idea to work

Worked example

A solenoid comparison doubles the measured current but also inserts a core. Does it isolate the current-strength effect?

Show the worked solution
  1. Current magnitude changes.
  2. Magnetic material changes too.
  3. The observation combines at least two influences.

Answer No; hold the core condition fixed to isolate current magnitude.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Design a comparison of solenoid field strength for current magnitudes 0.20 A and 0.40 A.

Give me a hint

Keep core, geometry, direction and observation position unchanged.

Compare my reasoning
  1. Measure the two currents with a suitable ammeter.
  2. Keep winding, core and position fixed.
  3. Use an appropriate strength-sensitive comparison and account for background.

A current-magnitude comparison with other conditions controlled.

Look for these in your work

  • State the current evidence.
  • Choose an observation suitable for strength.
2 · Independent

Design a comparison for reversal of straight-wire field direction.

Give me a hint

Change current sign but keep the magnitude and card view fixed.

Compare my reasoning
  1. Record the original conventional-current and compass directions.
  2. Reverse current at the same magnitude.
  3. Compare settled compass north-tip directions at the same marked points.

A fixed-geometry same-magnitude reversal isolates current direction.

Look for these in your work

  • Use consistent page convention.
  • Keep the observation points fixed.
3 · Transfer

A supply dial is unchanged while the wire warms, and a report assumes current is unchanged. Explain how to improve the control.

Give me a hint

Wire resistance can depend on its temperature.

Compare my reasoning
  1. Warming can change resistance.
  2. An unchanged dial need not give unchanged current.
  3. Measure and control current with suitable apparatus while limiting heating.

Use measured current and thermal controls rather than assuming the dial fixes current.

Look for these in your work

  • Name the confounding resistance change.
  • Identify the needed current measurement.

Common mistakes

  • Use measured current, not supply dial alone.
  • A core change is a second factor.
  • Compass direction is not a calibrated strength ratio.
Recall without your notes

What can you explain now?

Which comparison best isolates current direction?

Compare with the explanation

Reverse current at the same magnitude with geometry and view fixed.

It changes the sign while controlling magnitude, winding, observation point and viewing side.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Match the controlled factor and measurement to a direction or strength claim without confusing current, voltage and field.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Physics (9-1)

Course scope and assessment

491 sequenced Physics lessons provide 1473 guided, independent and application problems. 58 of 58 syllabus sections have full linked teaching sequences; 0 sections remain pending. Three earlier starter overviews remain available but are not counted as full sequences. The map covers all six subject areas for 2026–2028 and keeps review and assessment limits visible. This is available content, not full programme completion, an exam grade or certified mastery. Written practice is self-checked. Supervised practical experience, cumulative assessment and human subject-teacher review remain pending. Paper method exercises do not demonstrate practical competence or complete either practical-assessment route. This is the separate 9–1 qualification 0972; Cambridge states that its 2026–2028 subject content is otherwise the same as 0625. This 9–1 graded qualification is available only in a limited number of administrative zones. Confirm that your centre can enter you for this code and exam series with Cambridge International. The 2029 syllabus is separately published at https://www.cambridgeinternational.org/Images/764368-2029-syllabus.pdf and is not yet mapped here. This course supports exams in 2026, 2027 and 2028 only.