Learn in your language
Skip to content
IGCSE · Cambridge (CIE) · 0972

Describe a magnet and coil induction experiment

Specify apparatus, controlled observations and repeated comparisons for a school induction demonstration.

Electromagnetic induction pathway · 0972 (9–1) · 4.5.1
Exam scope and assessment notes

Core and Extended · Physics 0972, 2026–2028. Use the stated source, operating conditions and meter ranges. Written practice is self-checked. Human subject-teacher review, supervised practical competence and cumulative assessment remain pending. Cambridge states that IGCSE 0972 has the same subject content as IGCSE 0625, with 9–1 grading. This StudyForA pathway maps the 2026–2028 syllabus only. This 9–1 graded qualification is available only in a limited number of administrative zones. Confirm that your centre can enter you for this code and exam series with Cambridge International. Cambridge has published a separate syllabus for 2029. StudyForA has not reconciled that version yet; this page supports exams in 2026, 2027 and 2028 only.

Before you begin

  • Distinguish induced e.m.f. from current.
  • Read a signed centre-zero scale.

Work on paper. Try each question before revealing help, and explain why your method works.

Quick readiness check

What does a centre-zero detector allow you to observe?

What you will learn

  • Specify apparatus, controlled observations and repeated comparisons for a school induction demonstration.
  • Plan the apparatus, changing condition, stationary control and signed measurements of induction.
Original supplied centre-zero observations show approach +0.4 divisions, fixed hold zero and withdrawal −0.4 divisions with unchanged pole and terminals. Divisions are not volts or amperes without calibration. Written planning does not demonstrate practical competence.Unchanged pole and terminalsApproach: +0.4 divisionsChanging linked fieldFixed hold: zeroSteady linkingWithdrawal: −0.4 divisionsOpposite signed responseCalibration needed for A or V
Original supplied centre-zero observations show approach +0.4 divisions, fixed hold zero and withdrawal −0.4 divisions with unchanged pole and terminals. Divisions are not volts or amperes without calibration. Written planning does not demonstrate practical competence.

Use a sensitive detector and no supply in the receiver

Connect a school coil to a sensitive centre-zero galvanometer or suitable signed voltage detector. Move a bar magnet toward the coil, hold it still, then withdraw it. A deflection during movement and a zero return during the fixed hold demonstrate the changing-condition requirement. The receiving coil does not need an external electrical supply.

Keep coil orientation, magnet pole and detector connections unchanged while comparing approach and withdrawal. The two movements give opposite signs under the same connections. Swapping the approaching pole also reverses the sign. A meter sign is defined by its terminals; without that convention, positive does not name a universal direction.

Make comparisons controlled and repeatable

To compare speeds, keep the same magnet, coil, path and travel interval, move more slowly and more quickly, and compare peak deflection with repeated trials. To compare turns or magnet strength, change that one factor while holding speed, geometry and the detector circuit appropriately constant. Current measurements can also depend on circuit resistance.

The class demonstration uses suitable school apparatus, secure components and the teacher’s safety arrangements. Do not connect the receiving coil to mains. A written method checks planning and interpretation; it does not prove that the learner has performed an accurate practical or met the full practical-assessment requirements.

Pause and explain

With magnet pole and terminals unchanged, approach and withdrawal produce what comparison?

Put the idea to work

Worked example

A coil detector gives +0.4 divisions on approach, 0 during hold and −0.4 on equal-speed withdrawal. Interpret without a supplied current calibration.

Show the worked solution
  1. Movement changes the linked field.
  2. Opposite movement reverses the sign with unchanged terminals.
  3. Divisions alone are not amperes or volts.

Answer Opposite signed deflections during change; no sustained hold response; calibration is needed for physical units.

Try a topic test

Choose Easy, Normal or Difficult. Save your answers and open worked review after finishing.

Test this topic →

From guided practice to a new situation

Write your answer and reasoning first. Use a hint only if you are stuck. The model solution is for self-checking; your written work is not automatically marked.

1 · Guided

Write a short magnet–coil induction method including approach, hold and withdrawal.

Give me a hint

Include apparatus and expected observations, not just the conclusion.

Compare my reasoning
  1. Connect a suitable coil to a sensitive centre-zero detector.
  2. Approach, hold and withdraw the magnet with unchanged pole and terminals.
  3. Expect a deflection, zero steady hold and an opposite deflection.

A controlled approach–hold–withdrawal sequence demonstrates induction and sign reversal.

Look for these in your work

  • Name the detector.
  • Include a stationary control.
2 · Independent

How would you compare magnet movement speeds fairly using detector peaks?

Give me a hint

Hold magnet, path, coil and measurement setup fixed.

Compare my reasoning
  1. Use the same pole and travel path.
  2. Compare slow and fast motion under unchanged circuit conditions.
  3. Repeat and compare peak magnitudes.

Change speed alone and compare repeated peak magnitudes.

Look for these in your work

  • Control the other factors.
  • Do not use a single uncontrolled reading as proof.
3 · Transfer

A report gives deflections +3 and −3 divisions but claims these are exactly ±3 A without a calibration. Correct it.

Give me a hint

A scale number needs its physical-unit relationship.

Compare my reasoning
  1. The signs identify opposite detector responses.
  2. Divisions measure indicated scale positions.
  3. A current calibration is required to convert them to amperes.

Report ±3 divisions and opposite signs; exact amperes are not established.

Look for these in your work

  • Preserve the observed evidence.
  • Identify the missing calibration.

Common mistakes

  • Keep terminals and pole fixed for a comparison.
  • Detector divisions are not automatically A or V.
  • No mains supply is needed in the receiving coil.
Recall without your notes

What can you explain now?

Why include the stationary hold in the experiment?

Compare with the explanation

It controls for a magnet being present without changing linking.

It separates steady-field proximity from the changing condition producing induction.

After trying it yourself, choose your next review. This is your self-assessment.

Your review choice appears on Today. Sign in to sync it across devices.

Make it stick

Plan the apparatus, changing condition, stationary control and signed measurements of induction.

If you needed the solution, close it and solve the problem again from a blank page. A correct answer is stronger when you can explain the reason for each step.

Keep learning Physics (9-1)

Course scope and assessment

491 sequenced Physics lessons provide 1473 guided, independent and application problems. 58 of 58 syllabus sections have full linked teaching sequences; 0 sections remain pending. Three earlier starter overviews remain available but are not counted as full sequences. The map covers all six subject areas for 2026–2028 and keeps review and assessment limits visible. This is available content, not full programme completion, an exam grade or certified mastery. Written practice is self-checked. Supervised practical experience, cumulative assessment and human subject-teacher review remain pending. Paper method exercises do not demonstrate practical competence or complete either practical-assessment route. This is the separate 9–1 qualification 0972; Cambridge states that its 2026–2028 subject content is otherwise the same as 0625. This 9–1 graded qualification is available only in a limited number of administrative zones. Confirm that your centre can enter you for this code and exam series with Cambridge International. The 2029 syllabus is separately published at https://www.cambridgeinternational.org/Images/764368-2029-syllabus.pdf and is not yet mapped here. This course supports exams in 2026, 2027 and 2028 only.

StudyForA · Learn with understanding

Original teaching content and links to official sources. Check your exam year and qualification before using a resource.